Water tank, borewell and septic tank vastu: what the guides say
The vastu guides put the underground tank, sump and borewell in the north-east, the overhead tank in the south-west or west, and the septic tank most often in the north-west, never the north-east. They disagree on whether the septic tank may sit in the north and on the exact overhead spot, and their distances (JK Cement: 10–15 ft from the water tank) are far short of the 18 m IS 2470 sets between a soak pit and a drinking-water well.
What the published guides say
Each row is one guide, read on 13 November 2026, in our words. Vastu is a tradition, not an engineering code; the guides do not always agree.
| Guide | What it says |
|---|---|
| UltraTech Cement: vastu for water tanks | The overhead tank goes in the south-west, never the north-east or south-east; the underground tank or sump goes in the north-east, never the south-west. It prefers a concrete overhead tank to a plastic one, in dark shades such as blue, black or grey, and says to keep the septic tank away from the water tank. |
| JK Cement: septic tank vastu | The septic tank may go in the north or east (not the north-east corner) or the north-west corner, never the south-east, north-east or south-west. Its length should run east–west and its outlet face north or west. It should sit no higher than the plinth, 1–2 ft from the compound wall or plinth and 10–15 ft from the water tank. |
| Ashirvad (pipes maker): overhead water tank positions | The best place for the overhead tank is between the west and south-west, because a full tank is treated as heavy earth; the south is second and the west third, and the north-east never. Later the same page says the south-west corner should be avoided for tanks, and it notes that vastu's outcomes have no scientific validation. |
| Oriplast (pipes maker): borewell position as per vastu | The borewell belongs in the north-east, with east or north as good alternatives; the south-west, south-east and north-west are avoided. It also says to keep the borewell well away from septic tanks, consult a geologist, test the water and get local permission before drilling. |
| L&T Realty: vastu for home plans | One line only: avoid heavy storage or septic tanks in the north. |
| Square Yards: septic tank vastu | North-west is best, and it says never the north, north-east or east, yet also suggests east or south-east for an east-facing house and south or south-west as an alternative. The tank should be at least two feet from the boundary wall, no higher than the plinth, with no kitchen, puja room or bedroom above it. |
| The Goan (newspaper vastu column, Agnelo Pires): underground water tank | The underground tank goes in the north-east zone, but precisely north-of-north-east or east-of-north-east, never on the north-east to south-west diagonal. It must be outside the house, not touching the compound wall, and never in the south-west, south-east or north-west. |
| GaneshaSpeaks (astrology and vastu consultancy): water tank vastu | The overhead tank goes west or south-west, with south as a second choice, never the north-east or the middle; the underground tank goes north-east, or north or east, never north-west or south-east. It prefers black or blue tanks to plastic ones and a gap of one to two feet between the tank and the roof. |
Where they agree
- Underground water — sump, underground tank, borewell — goes to the north-east, with north or east as the fall-back (UltraTech, Oriplast, The Goan, GaneshaSpeaks).
- The overhead tank goes on the south-west or west side and never in the north-east (UltraTech, Ashirvad, GaneshaSpeaks).
- Underground water is kept out of the south-east and north-west (The Goan, GaneshaSpeaks, and Oriplast for the borewell).
- The septic tank stays away from the water tank and borewell (UltraTech, JK Cement, Oriplast), and no guide puts it in the north-east.
Where they differ
- The exact overhead spot: UltraTech says south-west; Ashirvad says between west and south-west but also to avoid the south-west corner, with south second; GaneshaSpeaks says west or south-west, with south second.
- A septic tank in the north: JK Cement allows the north or east (not the north-east corner) as well as the north-west; Square Yards says never the north, north-east or east; L&T Realty says avoid septic tanks in the north.
- A septic tank in the south or south-west: JK Cement says never; Square Yards offers south or south-west as an alternative while also saying to avoid the south.
- How exact the north-east must be: The Goan wants the underground tank north-of-north-east or east-of-north-east and never on the diagonal; the other guides just say north-east.
- Distances: JK Cement keeps the septic tank 10–15 ft from the water tank and 1–2 ft from the plinth, Square Yards two feet from the boundary wall; the Indian standard keeps the soak pit 18 m from a drinking-water well and 6 m from the house.
What the classical texts say
From translations of the old Sanskrit texts on building. They write different rules for each caste and for temples and kings' houses; today's guides give one rule for everyone, and many of their rules are not in the texts at all.
- Brihat Samhita 53.119 (tr. Chidambaram Iyer, 1884): Water to the north or north-east is good; water in the other directions is said to bring harm.
- Mayamata 27.105–108 (tr. Dagens, 1994): Cistern and tank on the squares next to the north-east corner.
- Manasara 36.27 (tr. Acharya, 1934): Wells around the south-east corner, unlike the other texts. None of the texts we read mentions overhead tanks, borewells or septic tanks.
What the rules and the evidence say, whatever the direction
Light, fresh air, drainage and a sound structure come first; these apply on every plot.
- A soak pit or dispersion trench must be at least 18 m from any drinking-water source such as a well, and at least 6 m from the nearest habitable building; soil decides the actual distance, and soak pits are not recommended in limestone or fissured rock. (IS 2470 (Part 2):1985, septic tank effluent disposal, cl. 5.3)
- The government sewerage manual sets 20 m between a septic tank's soak pit or trench and any drinking-water source, and at least 7 m from dwellings; soak pits suit only porous soil with the water table 2 m or more below ground. (CPHEEO Manual on Sewerage and Sewage Treatment 2013, Part A, §9.3.4.4)
- Twin leach pits of a pour-flush toilet need at least 3 m from a tube well or dug well in dry, fine soil, and 10 m where groundwater rises to within 2 m of the pit bottom. (CPHEEO Manual 2013, Part A, §9.3.3.3.1)
- The septic tank should be open to the sky, as far as possible from the outer wall of the building, out of swampy or flood-prone ground and reachable for cleaning. It needs at least 750 mm width, 1 m liquid depth and 1,000 litres, with length 2–4 times the width; cleaning every 6–12 months is desirable, at least every 2 years for a small house. (IS 2470 (Part 1):1985, cl. 3.3.1, 3.4.5 and 5.1)
- The septic tank's vent pipe, with a mosquito-proof mesh, must rise at least 2 m above the top of the highest building within 20 m; the tank needs watertight covers and two access manholes. (CPHEEO Manual 2013, Part A, §9.3.4.2)
- Roofs with access are designed for an imposed load of 1.5 kN/m² (0.75 kN/m² without access). A full 1,000-litre tank holds about 1,000 kg of water on a footprint of one or two square metres, far above that, so the tank's place belongs in the structural design. (IS 875 (Part 2):1987, Table 2 (tank weight is our arithmetic))
- Individual households drawing groundwater for drinking and domestic use do not need a CGWA no-objection certificate. (CGWA notification S.O. 3289(E), 24 Sep 2020, para 1.0(i))
- In Uttar Pradesh every domestic groundwater user must register online or with the block or municipal water committee (penalties do not apply to domestic users), and drilling agencies must be registered with the district council. (UP Ground Water (Management and Regulation) Act 2019, s.1(4), 10(2), 11(2), 17)
- Rooftop rainwater harvesting is compulsory on plots of 300 sq m and above where there is no shared recharge network; in new schemes, 100–300 sq m plots are exempt if their rain flows to the scheme's network. Waterlogged areas collect roof water instead of recharging the ground. (UP Building Bye-laws 2025, §13.1.2 (p. 135))
How we plan it on your plot
Whenever your plot allows, we follow these vastu preferences, and tell you plainly where we cannot, before the light, air and structure suffer. See our vastu house plans and plans for north-facing, south-facing, east-facing and west-facing plots, or the vastu overview (in Hindi: वास्तु के हिसाब से घर का नक्शा).
Common questions
Which direction is best for an overhead water tank as per vastu?
The south-west or west in every guide we read that covers it, and never the north-east. UltraTech names the south-west; Ashirvad prefers between west and south-west with south second; GaneshaSpeaks says west or south-west. Wherever it goes, a full 1,000-litre tank weighs about a tonne, so the structural engineer must plan for it.
Where should the underground water tank or sump be?
In the north-east, with north or east as the fall-back, according to UltraTech, GaneshaSpeaks and The Goan's vastu column. The Goan is stricter: north-of-north-east or east-of-north-east, never on the north-east to south-west diagonal, and not touching the compound wall. The guides keep it out of the south-west, south-east and north-west.
Which direction is best for a borewell?
The north-east, with east or north as alternatives, says Oriplast, matching the guides that put underground water in the north-east; it avoids the south-west, south-east and north-west. Whatever the direction, IS 2470 keeps any soak pit at least 18 m from a drinking-water borewell or well.
Where should the septic tank be as per vastu?
The north-west is the common choice (JK Cement, Square Yards), and no guide we read puts it in the north-east. They differ on the north: JK Cement allows north or east, while Square Yards and L&T Realty say not in the north. JK Cement also wants its length east–west and its outlet facing north or west.
What is the minimum distance between a septic tank and a borewell?
IS 2470 (Part 2) keeps a septic tank's soak pit or dispersion trench at least 18 m from any drinking-water well or borewell, and the CPHEEO sewerage manual says 20 m. Kerala's building rules, as reported, ask for 7.5 m between a well and a septic tank. The 10–15 ft some vastu guides give is far less.
How far from the house should a septic tank be?
IS 2470 says the tank should be as far as possible from the building's outer wall, open to the sky and reachable for cleaning, and its soak pit at least 6 m from the nearest habitable building (the CPHEEO manual says 7 m). The 1–2 ft from the plinth in some vastu guides is far closer.
Is rainwater harvesting compulsory for a house?
It depends on your state's bye-laws. Under Uttar Pradesh's 2025 bye-laws, rooftop rainwater harvesting is compulsory on plots of 300 sq m and above where there is no shared recharge network; in new schemes, 100–300 sq m plots are exempt if their rain flows into the scheme's network.
Do the old vastu texts mention borewells or septic tanks?
No. They speak of wells, cisterns and tanks: water to the north or north-east is good in the Brihat Samhita and Mayamata, while the Manasara puts wells near the south-east. Overhead tanks, borewells and septic tanks are modern and not in any text we read.
पानी की टंकी, बोरवेल और सेप्टिक टैंक का वास्तु
वास्तु गाइडों के अनुसार अंडरग्राउंड टैंक, संप और बोरवेल उत्तर-पूर्व (ईशान) में, और छत की टंकी दक्षिण-पश्चिम या पश्चिम में रखी जाती है; छत की टंकी को उत्तर-पूर्व में कोई गाइड नहीं रखती। सेप्टिक टैंक के लिए उत्तर-पश्चिम आम सलाह है, और उत्तर-पूर्व में इसे कोई नहीं रखता; उत्तर दिशा पर गाइडों में मतभेद है। वास्तु एक परंपरा है, पर दूरी के नियम सेहत के लिए हैं: IS 2470 के अनुसार सोक पिट पीने के पानी के कुएँ या बोरवेल से कम से कम 18 मीटर और घर से 6 मीटर दूर हो, और CPHEEO मैनुअल 20 मीटर कहता है। कुछ गाइडों की 10–15 फ़ुट की दूरी इससे बहुत कम है। 1,000 लीटर की भरी टंकी का वज़न लगभग एक टन होता है, इसलिए उसकी जगह स्ट्रक्चरल डिज़ाइन में तय होनी चाहिए। उत्तर प्रदेश के 2025 बायलॉज़ में 300 वर्ग मीटर या बड़े प्लॉट पर रेनवॉटर हार्वेस्टिंग ज़रूरी है। पूरी गाइड हिंदी में पढ़ें।
Vastu room by room
Kitchen vastuMaster bedroom vastuSleeping direction vastuToilet and bathroom vastuVastu doshPuja room vastuMain door vastuPlot shape and slope vastuStaircase vastuLiving room vastu
Sources, read 13 November 2026
UltraTech Cement: vastu for water tanks · JK Cement: septic tank vastu · Ashirvad (pipes maker): overhead water tank positions · Oriplast (pipes maker): borewell position as per vastu · L&T Realty: vastu for home plans · Square Yards: septic tank vastu · The Goan (newspaper vastu column, Agnelo Pires): underground water tank · GaneshaSpeaks (astrology and vastu consultancy): water tank vastu · Brihat Samhita 53.119 (tr. Chidambaram Iyer, 1884) · Mayamata 27.105–108 (tr. Dagens, 1994) · Manasara 36.27 (tr. Acharya, 1934) · IS 2470 (Part 2):1985, septic tank effluent disposal, cl. 5.3 · CPHEEO Manual on Sewerage and Sewage Treatment 2013, Part A, §9.3.4.4 · IS 2470 (Part 1):1985, cl. 3.3.1, 3.4.5 and 5.1 · IS 875 (Part 2):1987, Table 2 (tank weight is our arithmetic) · CGWA notification S.O. 3289(E), 24 Sep 2020, para 1.0(i) · UP Ground Water (Management and Regulation) Act 2019, s.1(4), 10(2), 11(2), 17 · UP Building Bye-laws 2025, §13.1.2 (p. 135)
Read how we research our guides. Spotted something out of date? Tell us and we will check it against the source.